I'm going to type the distance here, then I'm going to select the data flow V2, and then I'm going to click Save, which will bring up our web dashboard and make it ready for use. I will go to the Storage tab. Let me go to my device first, so that I can click here, then click the new device, and finally select the template name from the template. At this point, we are required to make use of this template in order to add a device. You can also tell me the name of the device that I currently use. Select the Create Now button.
Because you will be using the sensor in the water tank, at this point we need to connect all of these components in accordance with the circuit diagram. The sr04 ultrasonic sensor or the waterproof ultrasonic sensor are both acceptable options. If you do not want to use AC power, you will need to make use of the AC to DC converter; otherwise, you can supply the circuit with direct power of 5V. We will be utilizing the waterproof ultrasonic sensor for this project; however, you are more than welcome to utilize the ultrasonic sensor in accordance with the circuit before designing the PCB for this project.
This is the point where we will open up the board. Now is the time for us to assess the terminal. Simply put, it's a button located on the front sensor. Right-clicking and pressing the enter key will bring up one of our four key menus, from which you can choose the unit and make a number of adjustments (including the relay setting and the measurement unit). One of the sides of the sensor is shown here. You should now be familiar with all of the different ways an ultrasonic liquid level sensor can be used.
Consequently, I wish to investigate whether or not there is a side calibration for 24 hours. It's imperative that I move the door to position 25 on the track as soon as possible. I have calibrated it, which is why it is exactly at 25, which is the distance from the beam path, and how to calibrate this. So for this, I have calibrated it. I have uploaded the content, so could you please watch sludge level meter so that I can adjust sludge level meter appropriately after offering my apologies? I will make a drawing and a dac type, which stands for the distance amplitude curve, so how to draw the ds machine in this, so I must click to make the dhc, and I must enter the dac setting. How to enter the setting means that I must click the next group, and then click the next group, and finally I get the dac, and I must go to the setting menu, where the dac is located, which is in the customs. For instance, I mustBecause I want three holes, the curve needs to be three, and I have already prepared the calculation for the dac, which is a portion of the off-screen area. In point of fact, the clock from 1991 has three holes on either side.
This component will be utilized in the connection process. This is the portion on the side. Now we have black and red wires, which are the power supply for a DC 24V system. Therefore, we will start with these cables coming from it. Now we will basically turn the power on, and then we will connect the 24V DC power supply. This will allow us to turn the power on for our sensor. On the right terminal, you'll find the positive and negative terminals for a 24 V DC supply.
In addition to that, I described the version of every library. Install this version after you have finished doing that. You are going to need to enter the template ID device name as well as the authentication token, and then let me take you to the Blink account. I just need to click here to copy all of these specifics, and then I will paste them here. After that, I will need to enter the Wi-Fi name and password here. The significance of this aspect of the project cannot be overstated. The distance between the sensor and the bottom of the tank represents the distance between the full tank and the empty tank.