Describe in detail the maintenance of features of central dust collecting system

features of central dust collecting system Suitable for metallurgy, building materials, cement, machinery, chemical, electric power, light industry dust gas purification and material recovery. The use of separate chamber air pulse-jet ash removal technology overcomes the disadvantages of conventional features of central dust collecting system and separate chamber reverse dust collector. The dust removal rate is not bad, the emission concentration is low, the air leakage rate is small, the energy consumption is less, the steel consumption is less, the land area is less, the operation is stable, Good economic benefits.

Now, let's talk about the maintenance of the features of central dust collecting system in detail:

First, according to the water in the air bag to determine the regular discharge of water.

2. Check the use of wearing parts frequently according to the list of wearing parts.

Third, pay attention to check whether the sealing degree of the electric control box is intact, prevent water from entering the dust, and often clean up the dust in the electric control box.

4. Periodically check whether the equipment is operating normally according to the change and fluctuation of the equipment resistance.

5, often check whether the dust collector pulse cleaning system is working normally, if not normal, then focus on checking the pulse valve diaphragm loss, electromagnetic pulse valve failure, and timely replacement. The filter bag should be cleaned in time and replaced regularly.

Six, regularly supplement the lubricating parts of the equipment, the reducer six months to change the lubricating oil, bearing lubrication point supplement once a week.

Seven, according to the dust amount of the dust collector to determine the regular ash discharge maintenance time.

features of central dust collecting system What do we need to do when there is "dust"? Here, for you to talk about in detail:

First, when our operators see the features of central dust collecting system, the first thing we have to do is to stop the dust collector operation and close the dust collector.

Second, then we check the cause of dust collector, generally dust collector ash for the instant "ash" and continued "ash".

When there is "dust collecting", we have to check whether the filter bag is damaged, and we can judge which dust bag is damaged according to the number of ashes in the air outlet and the electromagnetic pulse valve, and the corresponding digit when the pulse controller operates. You can also use a flashlight from the upper box to see which dust bag leakage.

Fourth, if the filter bag of the dust collector is seriously damaged, it is necessary to replace most of the dust bag when the dust collector stops working.

Fifth, continuous ash is generally due to serious damage to the dust bag or the binding off of the dust bag. Another reason is the dust leakage caused by the features of central dust collecting system's upper mouth and the flower plate, the link between the flower plate and the flower plate is not tight enough.

Six, the instant "ash" is the dust collector filter bag in the case of damage is not serious, the emergence of ash.

In addition, when disassembling the bag, the cleaning controller should be closed, the top manhole door should be opened, and then the skeleton should be removed and the spring ring at the top of the bag should be knead into a concave shape, pull out the dust bag upward, and then the dust on the flower plate hole can be cleaned up to install a new dust bag. If it is only a momentary "ash", we can use the same method above to find out the broken filter bag, the filter bag is not badly damaged, we can repair the filter bag.

features of central dust collecting system https://www.kaisenfilter.com/Central-Dust-Collector

Posted in Default Category on August 07 2023 at 10:08 AM

Comments (0)

No login