Accurate fuel system testing is critical for maintaining the performance and efficiency of Cummins diesel engines. The PT (Pressure-Time) fuel system relies on precise measurements, and a properly calibrated PT test bench ensures reliable diagnostics and adjustments. If your test bench is out of calibration, fuel delivery and injection timing may be incorrect, leading to poor engine performance.
Here’s a step-by-step guide to calibrating your Cummins PT test bench for accurate results.
Step 1: Gather Necessary Tools & Equipment
Before starting, ensure you have:
A certified flow meter (for measuring fuel flow)
A calibration gauge set (for pressure verification)
A digital multimeter (for electrical checks)
Clean diesel fuel (free of contaminants)
The Cummins service manual for reference
Step 2: Check and Adjust Fuel Pressure
Connect the calibration gauge to the test bench’s pressure port.
Start the test bench and observe the pressure reading.
Compare it to the specified pressure range (typically between 30-60 psi for most PT systems).
If the pressure is off, adjust the pressure regulator valve until it matches Cummins’ specifications.
Step 3: Calibrate the Flow Meter
Install a certified flow meter in line with the test bench’s fuel supply.
Run fuel through the system at a controlled rate (e.g., 200 cc per 1,000 strokes).
Compare the test bench’s flow reading to the certified flow meter.
If there’s a discrepancy, adjust the flow meter calibration screw until readings align.
Step 4: Verify Electrical Components
Use a multimeter to check voltage and resistance in the test bench’s sensors and solenoids.
Ensure connections are clean and secure.
Replace any faulty wiring or sensors that affect calibration accuracy.
Step 5: Perform a Test Run
After calibration, test the bench with a known-good PT fuel pump:
Measure fuel flow rate and pressure output.
Compare results to Cummins’ published specs.
If readings are within tolerance, the calibration is successful.
Final Tips for Maintenance
Regularly recalibrate the test bench (every 6-12 months or after heavy use).
Always use clean fuel to prevent contamination.
Keep a calibration log to track adjustments over time.
By following these steps, you’ll ensure your Cummins PT test bench provides accurate diagnostics, helping maintain optimal engine performance. Proper calibration saves time, reduces costly errors, and extends the life of fuel system components.
For more detailed specifications, always refer to the official Cummins service manual for your engine model.