Endoscope camera module without led theoretical description

With the rapid development of industrial technology, the use of non-articulation way endoscope equipment in industry is increasingly widespread, which brings great convenience to life and industrial work and helps us improve the efficiency of industrial production. non-articulation way endoscope is a professional testing equipment that uses its unique nondestructive testing skills to help customers achieve efficient testing services.

What are the key factors that affect the detection of non-articulation way endoscope devices?

1. Lighting conditions

Lighting is the detection of the non-articulation way endoscope, which needs to meet the basic conditions to help the equipment better detect. Under normal conditions, it is required to detect that the color temperature of the lighting source is higher than 5600K and the lighting intensity is higher than 2600lm.

2. Probe position and angle

Generally speaking, the * * * * of the image is observed within the range of 5~25 mm from the detection area, so the scope camera module without led probe is often required to be as close to the observation point as possible, which can help customers to obtain * high-quality images. Detectors need to improve the efficiency and accuracy of detection according to the constant changes of probes in actual work.

3. The resolution, magnification and small defects that can be detected are the technical indicators of the scope camera module without led itself, which can directly affect the detection results.

4. Reflectivity of object surface

Different object surfaces have different reflectivity, and the material of the object is closely related to the roughness of the surface. Therefore, during actual detection, the intensity of the non-articulation way endoscope lighting should be determined according to the actual situation so as to obtain clear and effective results.

5. Access

When selecting the channel, it should be as close as possible to the position to be detected, and select the channel with short access length *; Minimize the number and degree of bending of the probe; The first consideration is the channel from top to bottom and from high to low; Give priority to wide channels; It is strongly recommended to use tooling to ensure the correct orientation of the probe in the channel; The method of observing while passing through shall be adopted to walk in the passage. The * small diameter of the channel determines the diameter of the non-articulation way endoscope probe entering the detection object; The length of the channel determines the required * small length for the non-articulation way endoscope probe to enter the inside of the detector; The bending degree of the channel depends on the bending radius of the non-articulation way endoscope probe.

non-articulation way endoscope https://www.hengal-tech.com/p-P9-series/33.html